Tempshield LOX-Glove Mid-Arm Cryogenic Gloves
Tempshield LOX-Glove liquid oxygen gloves provide splash protection for work involving cryogenic oxygen systems. This mid-arm style combines flame-resistant and static-dissipative properties with a waterproof liner. ASA SKU SLOXMID identifies the mid-arm option; select the required size before ordering. These gloves are intended for equipment handling and splash exposure, not immersion in liquid oxygen, liquid nitrogen or other cryogenic liquids.
Key Features
- Designed specifically for liquid oxygen splash hazards.
- Flame-resistant, static-dissipative construction.
- Seamless waterproof GORE-TEX liner, per Tempshield.
- Flexible construction for handling cryogenic equipment.
Applications
Tempshield lists servicing liquid oxygen systems, handling cryogenic valves, supply cylinders and transfer hoses, and filling or delivering cryogenic compressed gas cylinders. Applications include aerospace, industrial gas delivery, laboratories and biomedical operations where the task assessment specifies LOX protection.
Choose the Correct Fit
Tempshield instructs users to order their true size. The gloves must fit loosely enough to shake off in one motion if saturated with cryogenic fluid. A tight fit can reduce thermal protection. Check fit and removal before starting work, following your facility’s training and procedures.
Confirm the size-specific model on purchase orders. Mid-arm models include LOXMILMAM for medium, LOXMILMAL for large, LOXMILMAXL for extra large and LOXMILMAXXL for 2XL. Select coverage for the work position and other protective clothing; a longer glove does not make immersion acceptable.
For government purchasing, Tempshield lists NSN 8415-01-586-3712 for medium, 8415-01-586-4039 for large and 8415-01-586-4054 for extra large. Match the NSN to the required size rather than using one number for every variant. Keep the selected length, size and manufacturer model together in your procurement records for reordering.
Applicable OSHA Safety Requirements
OSHA 29 CFR 1910.138 — Hand Protection requires appropriate hand protection for harmful temperature extremes. Selection must consider glove performance, the task, working conditions, exposure duration and identified hazards. LOX splash protection does not authorize immersion.
OSHA 1910.132(d) — Hazard Assessment requires employers to assess hazards and select properly fitting PPE. Section 1910.132(f) requires training on when PPE is needed, how to use it, its limitations, and proper care. These requirements do not constitute OSHA product approval.
OSHA’s cold-environment glove selection guidance advises using manufacturer performance data and employee feedback. Follow Tempshield’s fit instructions so gloves can be removed quickly.
Read the Test Claims Correctly
The listed penetration test uses liquid nitrogen under specified test conditions. Its ten-minute duration is not an allowable immersion time or a guaranteed safe exposure period for the wearer. Flame resistance and static dissipation do not eliminate ignition hazards or replace oxygen-system safety procedures. Tempshield instructs users to follow all standard grounding procedures; see its liquid oxygen handling guidance. Tempshield currently states this product is not Category III CE certified.
Review Tempshield’s current LOX-Glove information and manufacturer catalog PDF, hosted by Princeton Cryo, for product details and selection guidance.
Explore ASA’s work gloves for other tasks requiring separately selected hand protection.
FAQ: Tempshield LOX Gloves
Can I immerse these gloves?
No. Tempshield prohibits immersion in cryogenic liquids.
Is this the elbow-length version?
No. SLOXMID is the mid-arm style.
Does waterproof mean immersion safe?
No. The liner does not change the immersion restriction.
Are these electrically insulating gloves?
Static dissipation does not establish electrical insulation.