Honeywell Organic Vapor Cartridges – Reliable Respiratory Protection for Organic Vapor Exposure
Honeywell North N75001L organic vapor cartridges are replacement cartridges for compatible North 5400, 5500, 7600 and 7700 series respirators. Their threaded connection and low-profile design support routine cartridge replacement in industrial respiratory protection programs. Use them for organic vapors identified by the workplace assessment and manufacturer’s selection guidance.
Honeywell North / N75001L
S75001L
Organic vapor (OV)
Pair — 2 cartridges
Threaded North N-Series
5400, 5500, 7600 and 7700
Key Features
- Low-profile shape helps keep cartridges out of the work zone.
- Threaded connectors attach to compatible North facepieces.
- Supports approved half-mask and full-facepiece configurations.
- Replaceable cartridges suit established facility PPE programs.
Common Uses & Applications
Potential applications include assessed organic vapor exposures during solvent handling, degreasing, adhesive use, coating work and industrial maintenance. Manufacturing, chemical-processing and oil and gas operations must evaluate the specific substances and concentrations. A task name or solvent smell alone cannot establish that this cartridge is appropriate.
Organic Vapor Cartridge or Particulate Filter?
N75001L is an organic vapor cartridge without an integral particulate filter. It does not independently provide N95 or P100 filtration for dust, mist or fumes. Jobs involving both vapors and particles require an approved cartridge/filter combination. It is not an acid gas, ammonia or universal gas cartridge. Confirm the complete assembly against the manufacturer’s approval label before use.
OSHA Requirements and Cartridge Replacement
OSHA 29 CFR 1910.134 requires an appropriate respiratory protection program for required workplace use, including hazard-based selection, medical evaluation, fit testing for tight-fitting facepieces, training and maintenance. Perform a user seal check every time the respirator is donned.
For gas/vapor cartridges without an appropriate end-of-service-life indicator, OSHA requires a change schedule based on objective information or data that ensures replacement before the end of service life. Do not rely on odor as the replacement schedule. If breakthrough, irritation or leakage occurs, leave the contaminated area and investigate before returning. These cartridges do not supply oxygen and are not for oxygen-deficient or IDLH atmospheres.
Manufacturer Documents
- Honeywell North cartridge product flyer (PDF) — model listing, connection and facepiece compatibility.
- N75001L NIOSH approval label and limitations (PDF) — approved component combinations and restrictions.
FAQ
Can these cartridges be used for painting?
Only when the coating ingredients and exposure assessment support their use. Spray mist needs appropriate particulate filtration; some coating hazards require a different respiratory system.
Can I install N75001L cartridges on MSA or 3M respirators?
No. Use only the North components and configurations identified in the approval documentation.
Is a respirator included?
No. These are replacement cartridges; the compatible facepiece is purchased separately.