DEWALT Reusable Concrete Fall-Protection Anchor

Dewalt
SKU:
DXFP845101
$94.00
(No reviews yet)
Current Stock:
Adding to cart… The item has been added

DEWALT Reusable Concrete Fall-Protection Anchor

The DEWALT DXFP845101 reusable concrete anchor provides a removable connection point for approved concrete fall-protection applications. Its expanding end fits a properly prepared 3/4-inch mounting hole. A spring-loaded trigger and retractor cables allow removal and relocation after use, subject to inspection and the manufacturer’s installation requirements.

Brand / Model
DEWALT / DXFP845101
Model
DXFP845101
Application
Concrete anchorage
Mounting-hole diameter
3/4 inch
Construction
Galvanized steel and aluminum
Listed user capacity
Up to 310 lb
Design
Reusable expanding anchor

Key Features

  • Removable design for relocation between approved locations
  • Spring-tensioned release mechanism
  • Horizontal, vertical and overhead applications as permitted by instructions

Common Uses & Applications

  • Concrete construction fall-protection planning
  • Industrial maintenance on approved concrete structures
  • Temporary anchorage where installation conditions can be verified

Selection and System Compatibility

The hole diameter alone does not determine whether an installation is suitable. Verify concrete strength, slab thickness, hole depth, edge distance, cleaning and loading direction using the model-specific manual. A qualified assessment of the supporting structure is essential. Do not use this anchor as a material-lifting point or assume that any drilled concrete hole is acceptable.

Manufacturer-Listed Standards

DFP’s declaration identifies ANSI Z359.18-2017 Type A; the current manual also lists CAN/CSA Z259.15-22. Product conformance does not establish the capacity of the structure or an incorrectly installed anchor. Follow the supplied label and approved installation instructions.

Inspection and Safety

Read the instructions before use. Inspect equipment before each use, remove damaged or fall-loaded equipment from service, and arrange prompt rescue. Follow applicable OSHA construction fall-protection requirements or general-industry personal fall-protection requirements.

Manufacturer Documents

FAQ

Can the anchor be reused?

Yes, subject to the manufacturer’s removal procedure, inspection and approved reinstallation conditions.

Is the mounting hole the only installation requirement?

No. Concrete condition, geometry, preparation and loading restrictions must also meet the manual.