FR Zipper Sweatshirt – 16 CAL/CM² Flame Resistant Work Hoodie

Portwest
SKU:
SUFR81
Availability:
Free Shipping
$113.95
(No reviews yet)
Safety is paramount in hazardous environments, and the FR Zipper Sweatshirt goes above and beyond with its inherently antistatic properties. This feature ensures that electrostatic discharges are minimized, adding an extra layer of protection to your workwear. FR wear is in compliance to EN 1149-5 standards, you can trust that this sweatshirt will protect you in environments where flammable materials and electrical risks are present.
Shipping:
Free Shipping
Current Stock:
Adding to cart… The item has been added

FR Zipper Sweatshirt: Flame-Resistant Protection and Comfort

All-Day Comfort with Flame-Resistant Protection

The Modaflame Knit FR zipper sweatshirt combines a soft cotton-blend feel with inherent flame resistance for assessed industrial work. Its navy fabric contains 60% modacrylic, 39% cotton and 1% carbon fiber. The manufacturer specifies 300 g/m² fabric, approximately 9 oz/yd², and an ASTM F1959 ATPV of 16 cal/cm².

Designed for Durability and Ease of Use

The full front zipper makes this FR hoodie easy to put on over compatible work layers. An attached hood adds coverage in cooler conditions, while rib-knit cuffs and waistband help limit drafts. Two front pockets provide hand warming and storage. Inherent flame resistance does not wash out, but damage, contamination and improper care can compromise protective performance.

Quick Buying Details

Brand / ModelPortwest / UFR81
ASA SKUSUFR81
Arc PerformanceARC 2; ASTM ATPV 16 cal/cm²
Fabric Blend60% modacrylic, 39% cotton, 1% carbon fiber
Closure / HoodFull front zipper / Attached hood
Color / StorageNavy / Two front pockets

Key Features

  • Inherent flame resistance
  • Antistatic fabric construction
  • Cotton content for comfort
  • Ribbed cuffs and hem
  • Convenient full-zip layering

Common Uses & Applications

  • Assessed electrical and utility work
  • Industrial maintenance and manufacturing
  • Oil, gas and refinery clothing programs
  • Construction requiring suitable FR layers

Manufacturer-Listed Standards

The Portwest UFR81 specification sheet PDF lists ASTM F1959 ATPV 16 cal/cm², EN ISO 11612 A1, B1, C1, F1 and EN 1149-5. It also lists IEC 61482-1-2 APC 1 and separate IEC 61482-1-1 results: ELIM 9.2 and ATPV 15 cal/cm².

Keep test methods and results together. APC 1 is a box-test classification, not the same as ARC 2. The current sheet does not list NFPA 2112 or a welding-specific certification; do not infer either from flame resistance alone.

OSHA Requirements and Safe Selection

OSHA 1910.335(a)(1)(i) requires electrical PPE appropriate to the hazards and exposed body parts. OSHA 1910.269(l)(8) addresses arc and flame protection for covered electric-power work.

Use the employer’s assessment to select the complete clothing system. This sweatshirt does not provide shock insulation, guaranteed burn prevention or a substitute for required arc-rated head and face protection.

Fit, Layering and Care

Check the Size Chart tab and current sizes. Confirm movement, sleeve coverage and compatibility with other PPE. Follow the sewn laundering label and inspect the zipper, seams and fabric before reuse.

FAQ

  • Is it a pullover? No. UFR81 has a full front zipper.
  • Can it be an outer layer? Yes, when the assessed hazards and complete clothing system permit.
  • Can I add layered arc ratings? No. Use a substantiated rating for the actual combination.
  • Does antistatic mean shock protection? No. EN 1149-5 addresses electrostatic properties, not electrical insulation.
  • Is it rated for extreme cold? No minimum-temperature rating is established.
  • Does permanent FR mean unlimited service life? No. Condition, contamination and care still determine continued suitability.

Safety is paramount in hazardous environments, and the FR Zipper Sweatshirt goes above and beyond with its inherently antistatic properties. This feature ensures that electrostatic discharges are minimized, adding an extra layer of protection to your workwear. FR wear is in compliance to EN 1149-5 standards, you can trust that this sweatshirt will protect you in environments where flammable materials and electrical risks are present.
General men's apparel, women's apparel and glove size chart. Read the measurements and tall/short adjustments in the text version below.
Read size chart measurements (text version)

This is the general size chart shown above. Use the specific product or manufacturer's size guide when provided.

Men's sizes — chest, waist, sleeve and inseam measurements are in inches.

  • XS: chest 30–32; waist 26; sleeve 31; inseam 29.
  • S: chest 34–36; waist 28–30; sleeve 32; inseam 29½.
  • M: chest 38–40; waist 32–34; sleeve 33; inseam 30.
  • L: chest 42–44; waist 36–38; sleeve 34; inseam 30½.
  • XL: chest 46–48; waist 40–42; sleeve 35; inseam 31.
  • 2XL: chest 50–52; waist 44–46; sleeve 36; inseam 31½.
  • 3XL: chest 54–56; waist 48–50; sleeve 37; inseam 32.
  • 4XL: chest 58–60; waist 52–54; sleeve 38; inseam 32½.
  • 5XL: chest 62–64; waist 56–58; sleeve 39; inseam 33.

Women's sizes — dress-size equivalents: XS 2–4; S 6–8; M 8–10; L 12–14; XL 16–18; 2XL 20–22.

Glove sizes — hand-measurement ranges shown in the chart: S 7½–8; M 8½–9; L 9½–10; XL 10½–11. Follow the glove manufacturer's measuring instructions for the specific model.

Regular, tall and short sizing

  • Regular: men's height 5 feet 8 inches to 6 feet.
  • Tall: men's height 6 feet 1 inch to 6 feet 3 inches. Add 2 inches to inseam and 1 inch to sleeve length.
  • Short: men's height 5 feet 3 inches to 5 feet 7 inches. Subtract 2 inches from inseam and 1 inch from sleeve length.

Measurement diagram: The image marks chest and waist across the torso, sleeve along the arm, inseam along the inside leg, hand across the palm and foot from heel to toe. It does not include a shoe-size conversion.