FR Coveralls – Arc Rated 9.5 cal, NFPA 2112 Workwear

Portwest
SKU:
SUBIZ1
Availability:
Free Shipping
$96.95
Bulk Pricing:

Below are the available bulk discount rates for each individual item when you purchase a certain amount

  • Buy 2 - 5 and get 3% off
  • Buy 6 - 9 and get 5% off
  • Buy 10 or above and get 7% off
(No reviews yet)
These coveralls are not just about comfort; they also meet stringent safety standards. Rated HRC Level 2 with an ARC Rating of 8, they provide essential protection against electrical hazards. Constructed with triple needle stitching, these coveralls are built to last, ensuring you can rely on them for repeated use. Available in Navy, Khaki, and Orange, they are a stylish and functional alternative to other fire-resistant clothing brands, such as Red Cap.
Shipping:
Free Shipping
Current Stock:
Adding to cart… The item has been added

Fire Resistant Contractors Coverall: Safety Meets Functionality

Bizweld Work FR coveralls provide flame-resistant, arc-rated coverage for contractor and industrial clothing programs. The 9.5 oz, 100% cotton fabric has an ATPV of 11.2 cal/cm², with CAT 2 listed by Portwest. A generous fit and side elastic waist accommodate movement during maintenance and field work.

The concealed snap front provides access without an exposed zipper. Snap-adjustable cuffs help set the wrist fit, while eight pockets organize small tools and essentials. Two chest pockets have snap closures, and the design includes a concealed phone pocket, rule storage and mic tabs.

Quick Buying Details

Brand / ModelPortwest / UBIZ1
ASA SKUSUBIZ1
Arc Rating / CategoryATPV 11.2 cal/cm² / CAT 2
FabricBizweld Work: 100% cotton, 9.5 oz
Closure / CuffsConcealed snaps / Adjustable snaps
Storage / FitEight pockets / Side elastic waist

Key Features

  • Generous coverall fit
  • Concealed snap front
  • Two snap-closure chest pockets
  • Concealed phone and rule storage
  • Radio mic tabs

Common Uses & Applications

  • Industrial contractor work
  • Oil and gas maintenance
  • Petrochemical operations
  • Assessed welding and related tasks
  • Electrical and renewable-energy maintenance

Manufacturer-Listed Standards

The Portwest UBIZ1 technical datasheet PDF lists NFPA 2112, ASTM F1506 and ASTM F1959 with ATPV 11.2 cal/cm². It also lists EN ISO 11611 Class 1 A1+A2 and EN ISO 11612 A1+A2, B1, C1, E2, F1.

Portwest references NFPA 70E for workplace electrical-safety applications. NFPA 70E guides safe work practices and PPE selection; it is not a standalone garment certification. Check the supplied garment label and required standards before issue.

OSHA Requirements and Selection

OSHA 29 CFR 1910.335(a)(1)(i) requires protective equipment appropriate to electrical hazards and exposed body parts. For covered electric-power work, 1910.269(l)(8) addresses arc and flame protection.

Select the complete PPE system through the hazard assessment. CAT 2 does not authorize every energized task, and this coverall does not insulate against electrical shock. Additional head, face, hand and foot protection may be required.

Fit and Care

Check the Size Chart tab and current ASA options. Allow room for required layers, then check reaching, bending and kneeling. Keep closures fastened as directed. Portwest specifies a mild wash up to 40°C, no bleach, no tumble drying, line drying, no ironing and no dry cleaning. Follow the sewn label and inspect for damage or contamination before reuse.

FAQ

  • Is the arc rating 9.5 or 11.2? Portwest lists ATPV 11.2 cal/cm². The 9.5 oz figure describes fabric weight.
  • Does it have a zipper? UBIZ1 uses a concealed snap front and snap-adjustable cuffs.
  • How many pockets are provided? Portwest lists eight pockets.
  • Is it fireproof? No. Flame resistance does not eliminate burn hazards.
  • Is it suitable for all welding? No. Match the documented Class 1 rating and complete PPE to the assessed process and exposure.
  • Can I add layered arc ratings? No. A layered system needs its own substantiated rating.

These coveralls are not just about comfort; they also meet stringent safety standards. Rated HRC Level 2 with an ARC Rating of 8, they provide essential protection against electrical hazards. Constructed with triple needle stitching, these coveralls are built to last, ensuring you can rely on them for repeated use. Available in Navy, Khaki, and Orange, they are a stylish and functional alternative to other fire-resistant clothing brands, such as Red Cap.
General men's apparel, women's apparel and glove size chart. Read the measurements and tall/short adjustments in the text version below.
Read size chart measurements (text version)

This is the general size chart shown above. Use the specific product or manufacturer's size guide when provided.

Men's sizes — chest, waist, sleeve and inseam measurements are in inches.

  • XS: chest 30–32; waist 26; sleeve 31; inseam 29.
  • S: chest 34–36; waist 28–30; sleeve 32; inseam 29½.
  • M: chest 38–40; waist 32–34; sleeve 33; inseam 30.
  • L: chest 42–44; waist 36–38; sleeve 34; inseam 30½.
  • XL: chest 46–48; waist 40–42; sleeve 35; inseam 31.
  • 2XL: chest 50–52; waist 44–46; sleeve 36; inseam 31½.
  • 3XL: chest 54–56; waist 48–50; sleeve 37; inseam 32.
  • 4XL: chest 58–60; waist 52–54; sleeve 38; inseam 32½.
  • 5XL: chest 62–64; waist 56–58; sleeve 39; inseam 33.

Women's sizes — dress-size equivalents: XS 2–4; S 6–8; M 8–10; L 12–14; XL 16–18; 2XL 20–22.

Glove sizes — hand-measurement ranges shown in the chart: S 7½–8; M 8½–9; L 9½–10; XL 10½–11. Follow the glove manufacturer's measuring instructions for the specific model.

Regular, tall and short sizing

  • Regular: men's height 5 feet 8 inches to 6 feet.
  • Tall: men's height 6 feet 1 inch to 6 feet 3 inches. Add 2 inches to inseam and 1 inch to sleeve length.
  • Short: men's height 5 feet 3 inches to 5 feet 7 inches. Subtract 2 inches from inseam and 1 inch from sleeve length.

Measurement diagram: The image marks chest and waist across the torso, sleeve along the arm, inseam along the inside leg, hand across the palm and foot from heel to toe. It does not include a shoe-size conversion.