Fendall Porta Stream II 16-Gallon Portable Emergency Eyewash Station
The Fendall Porta Stream II provides 15 minutes of hands-free emergency eye flushing without a plumbing connection. Its 16-gallon reservoir supplies a gravity-fed flow, making it an option for chemical handling areas, maintenance departments and temporary workstations where a self-contained eyewash fits the site assessment.
Model 32-000200-0000 includes saline concentrate for preparation before service. Pulling the nozzle strap starts flushing and leaves both hands available to hold the eyelids open. The station must be correctly filled, installed and maintained before it is ready for emergency use.
Key Features
- Self-contained gravity-fed flushing system.
- Full-flow nozzles for eye flushing.
- Large fill opening for cleaning and refilling.
- Metal hanging bracket included.
- 180-ounce saline concentrate and eyewash sign included.
Common Uses & Applications
- Industrial chemical handling areas.
- Maintenance shops without nearby plumbing.
- Temporary or remote workstations.
- Manufacturing and facility eyewash programs.
Installation and Readiness
Install the station level on a suitable support. The filled unit can weigh more than 150 pounds, so account for the load and obtain assistance when mounting. Use the manufacturer's bracket instructions; do not suspend the unit from a ceiling.
The manual calls for access within 10 seconds, on the same level as the hazard, with an unobstructed route. Strong acids or caustics may require placement immediately adjacent to the hazard. Assess the actual travel path rather than relying on a fixed distance.
OSHA and ANSI Eyewash Requirements
OSHA 29 CFR 1910.151(c) requires suitable facilities for immediate flushing or drenching where eyes or the body may be exposed to injurious corrosive materials. That regulation does not itself specify a 15-minute duration.
Honeywell describes the station's 0.4-gpm, 15-minute performance in relation to ANSI Z358.1. Site suitability also depends on installation, accessibility, flushing-fluid temperature and maintenance. An eyewash does not replace an emergency shower where body exposure requires one.
Solution and Maintenance
Prepare concentrate with potable water exactly as directed. Assign weekly inspections and keep records with the unit. Honeywell lists six-month replacement for its prepared saline solution; follow the fluid label and replace sooner after use, contamination or expiration. Other fluid options can require different intervals.
Manufacturer Instructions
Fendall Porta Stream II installation and operation manual (PDF) covers mounting, filling, employee training and inspection. Follow the emergency procedure and obtain medical attention after flushing.
FAQ
- Is this a six-gallon station? No. Porta Stream II has a 16-gallon reservoir.
- Does it need plumbing? No. It requires proper filling and installation before use.
- Can a personal eyewash bottle replace it? Personal bottles provide supplemental flushing and do not replace a suitable emergency eyewash station.